Vue de la page 250
GV200 @Track Air Interface Protocol
TRACGV200AN003 250
temperature range. 1 means inside of the predefined temperature range.
<Temperature Sensor device DATA>: The current temperature the sensor detected.
Event message +RESP:GTDOS uses this format.
+EVT,
Example:
2B 45 56 54 1C 01 FF D7 FF 00 69 04 04 0E 17 03 67 76 32 30 30 00 00 00 00 00 00 00 00 00 00
00 0D 0F 21 18 01 01 01 00 00 00 00 00 B7 00 3B 06 FC 59 64 01 E5 BB 58 07 DD 08 0C 0B 21
19 04 60 00 00 56 63 5A 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
07 DD 08 0C 0B 21 1C 00 42 41 29 0D 0A
Parameter
Length(byt
e)
Range/Format
Default
Message Header 4 +EVT +EVT
Message Type 1
Report Mask 4 00000000 – FFFFFFFF
Length 2
Device Type 1 04
Protocol Version 2 0000 – FFFF
Firmware Version 2 0000 – FFFF
Unique ID 8 IMEI/Device Name
External Power Supply
Voltage
2
Analog Input1 Voltage 2
Analog Input2 Voltage 2
Analog Input3 Voltage 2
Digital Input Status 1 00 – 1F
Digital Output Status 1 00 – 1F
Motion Status 1
0x11 | 0x12
0x21 | 0x22
0x41 | 0x42
0x16 | 0x1A
External GPS Antenna
Status | Satellites in View
1
Wave1 output id 1 1 – 4