GV200 @Track Air Interface Protocol
TRACGV200AN003 – 92 –
AT+GTJBS=
Example:
AT+GTJBS=gv200,1,,10,10,60,30,3600,1,30,,,,,001A$
Parameter
Length
(byte)
Range/Format Default
Password 4 – 6 '0' – '9' 'a' – 'z' 'A' – 'Z' gv200
Mode 1 0|1 0
Reserved 0
Siren up Timer(T1) 5 1 – 65535(×100ms) 10
Siren down Timer(T2) 5 1 – 65535(×100ms) 10
Siren Alarm duration(T3) 5 1 – 65535(sec) 60
Preparing Alarm Timer(T4) 5 1 – 65535(sec) 30
Cut fuel Timer(T5) 5 1 – 65535(sec) 3600
Need Judge Motion Sensor 1 0|1 1
Speed Limit 3 0 – 999km/h 30
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Serial Number 4 0000 – FFFF
Tail Character 1 $ $
<Mode>: Working mode.
0: Disable JBS function.
1: Enable JBS function
<Siren up Timer (T1)>: it pointed to the siren up length of time.
<Siren down Timer (T2)>: it pointed to the siren down length of time.
<Siren Alarm Duration (T3)>: it pointed to the siren Alarm length of time.
<Preparing Alarm Timer (T4)>: it pointed to the preparing alarm length of time.
<Cut fuel Timer (T5)>: it pointed to cut fuel length of time.
<Speed Limit>: the speed limit of cutting fuel.
<Need Judge Motion Sensor>: The GPS fixed fail is timeout, whether need judge motion
sensor state to cut fuel. If the <Need Judge Motion Sensor> set as 0, the machine state will
always judge the GPS fixed state.
0: Disable to need judge motion sensor.
1: Enable to need judge motion sensor.