GV200 @Track Air Interface Protocol
TRACGV200AN003 70
3.2.23. Excessive Idling Detection
The command AT+GTIDL is used to detect the engine excessive idling (stationary while ignition
on). To use this command, the ignition signal must be connected to the device. When the device
detects that the vehicle is entering into the idle status, it will report event message
+RESP:GTIDN to the backend server. When the vehicle leaves the idle status, the device will
report event message +RESP:GTIDF to the backend server.
AT+GTIDL=
Example:
AT+GTIDL=gv200,1,2,1,,,,,1,1,0,0,,,,,0015$
Parameter
Length(byte)
Range/Format
Default
Password 4 – 6 '0''9' 'a''z' 'A''Z' gv200
Mode 1 0|1 0
Time to Stationary <=2 1 – 30min 2
Time to Movement 1 1 – 5 min 1
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Output ID 1 0 – 4 0
Output Status 1 0|1 0
Duration <=3 0 – 255(×100ms) 0
Toggle Times <=3 0 – 255 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Serial Number 4 0000 – FFFF
Tail Character 1 $ $
<Mode>: Working mode.
0: Disable this function
1: Enable this function.
<Time to Stationary>: If the vehicle is detected to be stationary with ignition on for this time