GV200 @Track Air Interface Protocol
TRACGV200AN003 72
3.2.24. Hour Meter Counter
The command AT+GTHMC is used to measure time of use with each actuation of the ignition on.
To use this command, the ignition signal must be connected to the device. When the device sends
+RESP:GTFRI and +RESP:GTIGN and +RESP:GTIGF, <hour meter counter> will be sent in
these reports.
AT+GTHMC=
Example:
AT+GTHMC=gv200,1,12345:12:34,,,,,,,,,0016$
Parameter
Length(byte)
Range/Format
Default
Password 4 – 6 '0''9' 'a''z' 'A''Z' gv200
Hour Meter Enable 1 0|1 0
Initial Hour Meter Count 11 00000:00:00-99999:00:00 00000:00:00
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Serial Number 4 0000 – FFFF
Tail Character 1 $ $
<Hour Meter Enable>: Enable or disable hour meter counter function. If hour meter counter
function is enabled, hour meter count will be increased when the device is in ignition.
0: Disable hour meter counter function
1: Enable hour meter counter function
<Initial Hour Meter Count>: Initial hours meter count. It is formatted with 5 hour digits and
2 minute digits and 2 second digits and ranges from 00000:00:0099999:00:00. When
engine is on at the first time, <Hour Meter Count> which report in +RESP:GTFRI
/+RESP:GTIGN/+RESP:GTIGF will be increased based on this value.
The acknowledgment message of AT+GTHMC command:
+ACK:GTHMC,